Features
Constant moment beam and shear beam construction
Designed to resist overload damage
Moisture protected
Tension and compression loading
Specification
Rated capacities .............................300kgf, 500kgf, 1tf, 2tf
Rated output ....................................2mV/V±0.2%
Maximum safe overload ................200% of rated capacity
Combined error ..............................± 0.02% of rated output
Creep ................................................±0.1% of rated
output/hour
Zero balance ...................................± 1% of rated output
Compensated
temperature range......................... -10°C~+60°C/+14°F~+140°F
Recommended
excitation voltage ............................12V
Maximum
excitation voltage ...........................15V
Input terminal resistance .............Approximately 400Ω
Output terminal resistance ..........350Ω± 3.5Ω
Insulation resistance ....................Greater than 5000MΩ at DC50V
Temperature effect
Zero ..................................................0.007% of rated output/°C
Span .................................................0.002% of rated output/°CTyp.
Cable length 3m/118 inches (1&2t-5m/197 inches)
|